Powered by GoogleTranslate

Inspection Detail

Inspection: 100078104 - Napoleon Steel, Inc.

Inspection Information - Office: Columbus Area Office

 

Inspection Nr: 100078104
Report ID: 0522500
Date Opened: 12/24/1986

Site Address:
Napoleon Steel, Inc.
7019 South High Street
Lockbourne, OH 43137

Mailing Address:
P.O. Box 9115, 5544 Fairlane Drive, Cincinnati, OH 45209

Union Status: Union

SIC:1791

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 12/29/1986

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 03/29/1988


Related Activity
Type Activity Nr Safety Health
Accident 360681399
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 1 5
Current Violations 3 1 4
Initial Penalty $2,800 $0 $0 $0 $0 $2,800
Current Penalty $300 $0 $0 $0 $0 $300
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 19260021 B02 02/13/1987 02/23/1987 $0 $700 $0 02/25/1987 F - Formal Settlement  
2. 01002 Serious 19260550 B02 02/13/1987 02/23/1987 $100 $700 $0 02/25/1987 F - Formal Settlement  
3. 01003 Serious 19260550 B02 02/13/1987 02/16/1987 $100 $700 $0 02/25/1987 F - Formal Settlement  
4. 01004 Serious 19260550 B02 02/13/1987 02/16/1987 $100 $700 $0 02/25/1987 F - Formal Settlement  
5. 02001 Other 19260025 A 02/13/1987 02/16/1987 $0 $0 $0 02/25/1987 F - Formal Settlement Citation has been deleted.

Investigation Summary

Investigation Nr: 14570410
Event: 12/23/1986
CRANE-LIFTED WALL FELL, STRIKING EMPLOYEE

THREE EMPLOYEES WERE ASSISTING IN THE LIFT OF AN 18 FOOT, 6 INCH BY 30 FOOT PRETIED STEEL REINFORCING WALL. THE WALL CONSISTED OF 54 VERTICAL NUMBER 8 REBAR AND 12 HORIZONTAL NUMBER 5 REBAR. IT WEIGHED APPROXIMATELY 1.47 TONS. THE LIFT WAS MADE USING A P.H. 70 TON CRAWLER CRANE, NUMBER C-27. THE WALL WAS RIGGED TO THE CRANE HOOK USING A TWO-WAY WIRE ROPE SPREADER ATTACHED TO THE TOP HORIZONTAL MEMBER. THE WEIGHT OF THE WALL, AS THE LIFT WAS MADE, CAUSED THE ENTIRE STRUCTURE TO BOW, EVENTUALLY SNAPPING THE TIE WIRES. THE WALL THEN BROKE UP AND FELL TO THE GROUND, STRIKING EMPLOYEE #1. EMPLOYEE #1 SUSTAINED HEAD INJURIES WHICH SUBSEQUENTLY RESULTED IN HIS DEATH. A FOUR-WAY SPREADER SHOULD HAVE BEEN USED BECAUSED IT WOULD HAVE MORE EQUALLY BALANCED THE WEIGHT OF THE LOAD, THUS PREVENTING THE WALL FROM BOWING AND BREAKING UP.

Keywords: HEAD, WORK RULES, CONSTRUCTION, STRUCK BY, FALLING OBJECT, SPREADER BAR, CRANE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 100078104 Fatality Fracture Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close