Powered by GoogleTranslate

Inspection Detail

Inspection: 100074053 - Empire-Detroit Steel, Div. Of Cyclops Corp.

Inspection Information - Office: Toledo Area Office

 

Inspection Nr: 100074053
Report ID: 0524700
Date Opened: 01/06/1987

Site Address:
Empire-Detroit Steel, Div. Of Cyclops Corp.
913 Bowman Street
Mansfield, OH 44905

Mailing Address:
, , 00000

Union Status: Union

SIC:3312

NAICS: 0 


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/13/1987

Emphasis:

Case Closed: 03/13/1987


Related Activity
Type Activity Nr Safety Health
Referral 900977067 Yes

Investigation Summary

Investigation Nr: 14570915
Event: 01/06/1987
Employee burned by molten metal and steam

Employee #1, the supervisor, was tilting an electrical arc furnace to check for a water leak in the bottom panel when the furnace exploded. He was burned by molten metal and steam. The power had been shut off for between 45 and 60 minutes, and all workers except Employee #1 had left the area.

Keywords: BURN, FURNACE, WORK RULES, STEAM, EXPLOSION, MOLTEN METAL

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 100074053 Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close