Powered by GoogleTranslate

Inspection Detail

Inspection: 100070259 - General Motors Corp B O C Group Van Plant

Inspection Information - Office: Cleveland Area Office

 

Inspection Nr: 100070259
Report ID: 0522300
Date Opened: 10/08/1985

Site Address:
General Motors Corp B O C Group Van Plant
2300 Hallock Young Rd
Lordstown, OH 44482

Mailing Address:
, , 00000

Union Status: Union

SIC:3711

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/01/1985

Emphasis:

Case Closed: 06/04/1987


Related Activity
Type Activity Nr Safety Health
Accident 360686968
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $560 $0 $0 $0 $0 $560
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19100106 E02 IVA 11/05/1985 11/08/1985 $0 $560 $0 11/25/1985 R - Review Commission  
2. 01001B Serious 19100106 E06 I 11/05/1985 12/17/1985 $0 $0 $0 11/25/1985 -  
3. 01001C Serious 19100145 C03 11/05/1985 12/17/1985 $0 $0 $0 11/25/1985 -  

Investigation Summary

Investigation Nr: 14522635
Event: 10/04/1985
FIRE AND EXPLOSION

THE EMPLOYEES WERE USING FLAMMABLE LIQUIDS IN THE AREA. THERE WAS AN UNMARKED DRUM OF METHYL ALCOHOL (1/2 FULL), WITH A ONE INCH DIAMETER OPENING (VENT) IN THE TOP OF THE BARREL. THEY WERE DISPENSING FROM THIS BARREL VIA A PUMP TO FILL TANKS IN VANS WITH WINSHIELD WASHER FLUID. THE BARREL HAD BEEN MOVED TO AN AREA WHERE SMOKING WAS ALLOWED. WELDING WAS BEING DONE ACROSS THE AISLE. A FIRE STARTED IN THE GRATE WHICH CATCHES ANY LEAKS FROM VANS BEING TESTED. EMPLOYEE #1, WHO WAS STANDING ON THE GRATE TALKING TO EMPLOYEE #2, CAUGHT FIRE. HE RAN ONE WAY AND EMPLOYEE #2 THE OTHER. THE DRUM OF METHYL ALCOHOL EXPLODED, BURNING EMPLOYEE #2.

Keywords: METHYL ALCOHOL, FLAMMABLE LIQUID, FIRE, WELDING, EXPLOSION, SMOKING

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 100070259 Hospitalized injury Burn/Scald(Heat) Occupation not reported
2 100070259 Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close