Inspection Detail
Inspection: 100070002 - Akro Corp
Inspection Information - Office: Cleveland Area Office
Site Address:
Akro Corp
1212 7th St
Canton, OH 44707
Mailing Address:
, , 00000
Union Status: Union
SIC:3069
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: Y
Ownership: Private
Safety/Health: Safety
Close Conference: 07/18/1985
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 08/27/1985
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360568471 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 2 | 2 | ||||
Current Violations | 2 | 2 | ||||
Initial Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Other | 19100303 G02 III | 07/31/1985 | 08/03/1985 | $0 | $0 | $0 | - | ||
2. | 01002 | Other | 19100303 H02 | 07/31/1985 | 08/03/1985 | $0 | $0 | $0 | - |
Investigation Summary
A LABORER WAS HANDLING A 14-FOOT LENGTH OF ANGLE IRON IN A STORAGE YARD. THE STORAGE YARD WAS ADJACENT TO A FENCED AREA ENCLOSING ELECTRIC TRANSFORMERS. THE EMPLOYEE APPARENTLY SWUNG THE ANGLE IRON PAST OR THROUGH THE FENCE, AND THE ANGLE IRON CONTACTED ENERGIZED PARTS OF THE TRANSFORMER INSTALLATION. THE LABORER WAS ELECTROCUTED.
Keywords: METAL RAIL, ELECTRICAL, ELECTROCUTED, TRANSFORMER, E GI IC
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 100070002 | Fatality | Electric Shock | Laborers, except construction | ||
2 | 100070002 | Fatality | Electric Shock | Occupation not reported |