Inspection: 100039726 - Spring Lake Camping Resort
Inspection Information - Office: Wichita Area Office
Site Address:
Spring Lake Camping Resort
2 Miles West Of Halstead, Ks Of U.S. Hwy 50
Halstead, KS 67056
Mailing Address:
Route 2 Box 24, Halstead, KS 67056
Union Status: NonUnion
SIC:7033
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 10/23/1985
Emphasis:
Case Closed: 01/21/1986
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360638290 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $640 | $0 | $0 | $0 | $0 | $640 |
| Current Penalty | $640 | $0 | $0 | $0 | $0 | $640 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001A | Serious | 19100110 I02 V | 10/31/1985 | 11/03/1985 | $640 | $640 | $0 | - | ||
| 2. | 01001B | Serious | 19100110 I02 V | 10/31/1985 | 11/03/1985 | $0 | $0 | $0 | - |
Investigation Summary
ALL COMPANY EMPLOYEES WERE ATTENDING A SALES PRESENTATION IN THE OFFICE OF A CONVERTED FARM HOUSE. AN ACCUMULATION OF PROPANE GAS IN THE BASEMENT WAS IGNITED BY A SPARK FROM AN ELECTRIC MOTOR. THE RESULTANT EXPLOSION TOTALLY DEMOLISHED THE BUILDING. AN UNCAPPED OUTLET IN THE PROPANE FUEL LINE, FORMED WHEN THE LINE WAS CUT DURING REMODELING OF THE FARM HOUSE, WAS THE SOURCE OF THE PROPANE LEAK. THE COMPANY'S PRESIDENT HAD ATTEMPTED TO LIGHT THE PROPANE FED FLOOR FURNACE WHEN HE WAS CALLED AWAY, LEAVING THE VALVE ON AND CONSEQUENTLY ALLOWING THE PROPANE GAS TO ACCUMULATE IN THE BASEMENT.
Keywords: ELECTRIC MOTOR, OPEN VALVE, EXPLOSION, PROPANE, SPARK
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 100039726 | Fatality | Fracture | Occupation not reported | ||
| 2 | 100039726 | Hospitalized injury | Dislocation | Occupation not reported | ||
| 3 | 100039726 | Non Hospitalized injury | Bruise/Contus/Abras | Occupation not reported | ||
| 4 | 100039726 | Non Hospitalized injury | Bruise/Contus/Abras | Occupation not reported | ||
| 5 | 100039726 | Non Hospitalized injury | Bruise/Contus/Abras | Occupation not reported | ||
| 6 | 100039726 | Non Hospitalized injury | Bruise/Contus/Abras | Occupation not reported | ||
| 7 | 100039726 | Non Hospitalized injury | Bruise/Contus/Abras | Occupation not reported | ||
| 8 | 100039726 | Non Hospitalized injury | Puncture | Occupation not reported | ||
| 9 | 100039726 | Non Hospitalized injury | Bruise/Contus/Abras | Occupation not reported | ||
| 10 | 100039726 | Non Hospitalized injury | Bruise/Contus/Abras | Occupation not reported | ||
| 11 | 100039726 | Hospitalized injury | Other | Occupation not reported | ||
| 12 | 100039726 | Hospitalized injury | Fracture | Occupation not reported | ||
| 13 | 100039726 | Hospitalized injury | Dislocation | Occupation not reported | ||
| 14 | 100039726 | Hospitalized injury | Fracture | Occupation not reported | ||
| 15 | 100039726 | Hospitalized injury | Fracture | Occupation not reported | ||
| 16 | 100039726 | Hospitalized injury | Fracture | Occupation not reported | ||
| 17 | 100039726 | Hospitalized injury | Fracture | Occupation not reported | ||
| 18 | 100039726 | Hospitalized injury | Fracture | Occupation not reported |