Powered by GoogleTranslate

Inspection Detail

Inspection: 100025816 - Colorado Applied Research, Inc.

Inspection Information - Office: Denver Area Office

 

Inspection Nr: 100025816
Report ID: 0830500
Date Opened: 05/16/1988

Site Address:
Colorado Applied Research, Inc.
2295 Busch Ave.
Colorado Springs, CO 80904

Mailing Address:
2902 W. Colorado Ave., Colorado Springs, CO 80904

Union Status: NonUnion

SIC:8731

NAICS: 0 


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 05/26/1988

Emphasis:

Case Closed: 06/24/1988


Related Activity
Type Activity Nr Safety Health
Referral 901210419 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 4 7
Current Violations 3 4 7
Initial Penalty $600 $0 $0 $0 $0 $600
Current Penalty $600 $0 $0 $0 $0 $600
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 5A0001 06/10/1988 06/16/1988 $210 $210 $0 -  
2. 01002 Serious 5A0001 06/10/1988 06/30/1988 $210 $210 $0 -  
3. 01003 Serious 5A0001 06/10/1988 06/25/1988 $180 $180 $0 -  
4. 02001 Other 19100109 C02 III 06/10/1988 06/20/1988 $0 $0 $0 -  
5. 02002 Other 19100109 C05 VII 06/10/1988 06/22/1988 $0 $0 $0 -  
6. 02003A Other 19100134 B01 06/10/1988 07/01/1988 $0 $0 $0 -  
7. 02003B Other 19100134 B06 06/10/1988 06/16/1988 $0 $0 $0 -  
8. 02003C Other 19100134 B08 06/10/1988 07/01/1988 $0 $0 $0 -  
9. 02003D Other 19100134 E05 06/10/1988 07/01/1988 $0 $0 $0 -  
10. 02004 Other 19100151 C 06/10/1988 06/25/1988 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 14428973
Event: 05/16/1988
Employee burned by experimental propellant

At approximately 11:30 a.m. on April 18, 1988, a research propellant mixture was overheated during a heating and combining procedure, causing it to harden and crust over. The rejected 7 to 8 kg batch of propellant was placed outside the research trailer on a stainless steel table. After a short interval, the propellant started to smoke and emit a white powder. Employee #1 walked toward the propellant to investigate. When he was within 15 feet of the material, he raised his face shield to get a better look. At that time, the heat buildup within the crusted-over propellant batch deflagrated. Employee #1 sustained 1st-and 2nd-degree burns to his face and right hand.

Keywords: BURN, PPE, WORK RULES

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 100025816 Non Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.