Powered by GoogleTranslate

Inspection Detail

Inspection: 100022169 - Centaur Cleaners

Inspection Information - Office: Denver Area Office

 

Inspection Nr: 100022169
Report ID: 0830500
Date Opened: 12/03/1985

Site Address:
Centaur Cleaners
1310 Centaur Village Drive
Lafayette, CO 80026

Mailing Address:
1310 Centaur Village Drive, Lafayette, CO 80026

Union Status: NonUnion

SIC:7216

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 01/17/1986

Emphasis:

Case Closed: 04/28/1986


Related Activity
Type Activity Nr Safety Health
Referral 900658097 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $120 $0 $0 $0 $0 $120
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19100132 A 01/30/1986 02/18/1986 $0 $120 $0 I - Informal Settlement  
2. 01001B Serious 19100133 A01 01/30/1986 02/18/1986 $0 $0 $0 I - Informal Settlement  
3. 01001C Serious 19100134 A02 01/30/1986 02/18/1986 $0 $0 $0 I - Informal Settlement  
4. 01001D Serious 19100134 B08 01/30/1986 03/04/1986 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 14426894
Event: 12/03/1985
EMPLOYEE INHALED PERCHLOROETHYLENE USED IN DRY CLEANING

EMPLOYEE #1 WAS ALONE WORKING IN A DRY CLEANING ESTABLISHMENT. HE WAS INVOLVED IN THE BOIL-DOWN PROCESS, WHICH RECYCLES THE PERCHLOROETHYLENE SO THAT IT CAN BE REUSED. IT IS THEORIZED THAT, DUE TO A MALFUNCTION IN THE MANIFOLD UNIT OR CONDENSER UNIT, THE PROCESS "TOOK OFF" BEFORE EMPLOYEE #1 COULD REACT. THE PRESSURE BUILT UP AND CAUSED HOT PERCHLORETHYLENE TO BE FORCED OUT OF THE UNIT THROUGH THE RELIEF VALVE AND AROUND THE SEALS. THE HOT PERCHLOROETHYLENE COMPLETELY COVERED EMPLOYEE #1, WHO WAS NOT WEARING ANY PERSONAL PROTECTIVE EQUIPMENT. EMPLOYEE #1 RAN TOWARD THE BATHROOM BUT WAS OVERCOME BEFORE HE COULD GET THERE. HE WAS DISCOVERED BY ANOTHER EMPLOYEE, NEWLY ARRIVED AT WORK, IN ABOUT 1 INCH OF LIQUID. EMPLOYEE #1 SUFFERED LUNG DAMAGE, THIRD DEGREE BURNS ON HIS BODY AND WAS BRAIN DEAD. HE DIED IN INTENSIVE CARE AFTER LIFE SUPPORT SYSTEMS WERE DISCONNECTED.

Keywords: BURN, RESPIRATORY, LUNG, PPE, INHALATION, DRY CLEANING, PERCHLOROETHYLENE, HIGH PRESSURE, TOXIC FUMES

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 100022169 Fatality Poisoning(Systemic) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close