Accident Summary Nr: 999821 - EMPLOYEE KILLED WHEN CAUGHT IN RIBBON BLENDER

Accident Summary Nr: 999821 -- Report ID: 0552700 -- Event Date: 11/03/1989
Inspection NrDate OpenedSICNAICSEstablishment Name
10777616311/06/198920130Tony Downs Foods

Abstract: Employee #1 reached into a ribbon blender in the unload position and was drawn into the unit. A coworker heard him yell and hit the stop switch. Employee #1 was pinned to the bottom of the tank, which had to be cut apart to free him. The ribbon blender was equipped with a safety interlock and jog switch. The interlock was taped down with fiberglass tape and had been this way for a long time. This unit had been cited for a defective interlock during OSHA inspection on March 6, 1986.

Keywords: CAUGHT BY, INTERLOCK, TANK

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 107776163 Fatality Other Mixing and blending machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.