Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 981209 - ELECTRIC SHOCK - GROUND FAULT IN PLASTIC MOLDING MACHINE

Accident Summary Nr: 981209 -- Report ID: 0551800 -- Event Date: 08/10/1989
Inspection NrDate OpenedSICNAICSEstablishment Name
10792964808/10/198930820R & R Plastics

Abstract: AN EMPLOYEE WAS INSTALLING A WATER HEATER (IMS, SERIAL NO. 523853616) ON A TOSHIBA MODEL ISE 170-9A PLASTIC INJECTOR MOLDING MACHINE (SERIAL NO. 557702). THE EXISTING WATER HEATER APPARENTLY DEVELOPED A GROUND FAULT WHEN THE HEATING COIL FAILED. THE WATER HEATER, WHICH WAS CONNECTED BY A FLEXIBLE CORD OFF A PIGTAIL FROM THE MOLDING MACHINE, WAS WIRED CORRECTLY, EXCEPT THAT THE EQUIPMENT GROUNDING CONDUCTOR ON THE PIGTAIL HAD NOT BEEN CONNECTED. THE MOLDING MACHINE AND THE WATER HEATER WERE SUPPLIED BY A 3-PHASE, 480-VOLT, 100-AMPERE CIRCUIT. THE FUSES PROTECTING THE CIRCUIT DID NOT OPEN ON THE GROUND FAULT. THE EMPLOYEE TOUCHED THE ENERGIZED PORTION OF THE WATER HEATER WHILE HE WAS IN CONTACT WITH THE GROUNDED MOLDING MACHINE. THE EMPLOYEE WAS ELECTROCUTED. HE HAD BURN MARKS ON HIS RIGHT HAND AND ON HIS LEGS ABOVE THE KNEES.

Keywords: ELECTRICAL, E GI VII, ELECTROCUTED, GROUND FAULT, EQUIPMENT GROUNDING, ELEC EQUIPMENT--MISC

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 107929648 Fatality Electric Shock Machinery maintenance occupations

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.