Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 967265 - Employee injured in air tank explosion

Accident Summary Nr: 967265 -- Report ID: 0950632 -- Event Date: 12/24/1992
Inspection NrDate OpenedSICNAICSEstablishment Name
11999043012/24/199217710W A Seeger Inc

Abstract: The employer is engaged in parking lot maintenance and owns two identical portable paint stripping machines. The three major components of the machine are an air compressor unit, a paint supply can, and a 4 HP gas engine. The air tanks of the air compressor units did not have permits to operate and both were over 1 1/2 cu ft in capacity. One air tank exploded and Employee #1 sustained a fractured leg. The air tank did not meet ASME code and had deteriorated due to poor maintenance.

Keywords: COMPRESSOR, FRACTURE, INADEQUATE MAINT, WORK RULES, CONSTRUCTION, EXPLOSION, TANK, EQUIPMENT APPROVAL, LEG

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 119990430 Hospitalized injury Fracture Painting and paint spraying machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.