Accident Summary Nr: 953059 - Employee burned by ignited paint vapors

Accident Summary Nr: 953059 -- Report ID: 0355118 -- Event Date: 02/06/1990
Inspection NrDate OpenedSICNAICSEstablishment Name
10576185202/09/199075320Bill'S Classic Cars

Abstract: At 11:00 a.m on February 6, 1990, Employee #1 was inside a Binks spray booth, which is used to paint vehicles, cleaning paint residue off its sides with water. He had finished painting a vehicle approximately 2 hours earlier. Meanwhile, flammable vapors had accumulated in the spray booth and shop area of the facility. The exhaust fan in the spray booth was off and the bay doors of the shop were closed. A gas-powered water heater, located within 20 ft of the spray booth, apparently ignited the vapors. The fire followed the vapor path back to the spray booth where Employee # 1 was located. He was engulfed by the fire and suffered burns over 80 percent of his body, for which he was hospitalized.

Keywords: BURN, VENTILATION, FLAMMABLE VAPORS, WORK RULES, CLEANING, FIRE, PAINT, SPRAY BOOTH

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 105761852 Hospitalized injury Burn/Scald(Heat) Automobile body and related repairers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close