Accident Report Detail
Accident Summary Nr: 922765 - Two employees drown in lagoon
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 109306621 | 01/29/1995 | 2077 | 0 | Georgia Proteins, Inc. |
Abstract: Just after lunch on January 28, 1995, Employees #1 and #2 went out onto lagoon #3 to check a problem with a transfer pump and determined that the cause was a bad motor. Around 2:00 p.m., a pontoon was brought from another lagoon to lagoon #3. A new motor, weighing 480 lb, was tied to the right pontoon at the front. A full set of oxygen and acetylene bottles was tied to the rear, in preparation for burning the nuts off the motor. Around 3:15 p.m., Employees #1 and #2 got on the boat and headed out to change the motor. At around 4:10 p.m., an employee left the plant and saw the men working on the motor. Around 4:30 p.m., another employee left the plant and noticed that the pontoon had capsized; he returned to the plant and contacted management to initiate a rescue. It took until around 4:00 p.m. the next day to recover the bodies. Employees #1 and #2 had drowned. They were not wearing life vests.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 109306621 | Fatality | Other | Occupation not reported | ||
| 2 | 109306621 | Fatality | Other | Occupation not reported |
Translate