Accident Report Detail
Accident Summary Nr: 829077 - Employee's finger amputated by malfunctioning press brake
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 104240106 | 11/30/1989 | 3548 | 0 | John Deere Ottumwa Works |
Abstract: Employee #1 was operating a press brake that was running small pieces measuring 1/2 in. by 1 1/2 in. He was also using hand tools. The press was equipped with a light curtain. The press and light curtain were shut off, but the main switch was still on. When the employee wiped out the bending fixture with his finger, the press cycled and his finger was amputated. It was later found that the foot switch malfunctioned and caused the press to cycle.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 104240106 | Hospitalized injury | Amputation | Punching and stamping press machine operators |
Translate