Accident Summary Nr: 813923 - ELECTRIC SHOCK - GROUND FAULT IN CONVEYOR CIRCUIT

Accident Summary Nr: 813923 -- Report ID: 0552700 -- Event Date: 08/27/1993
Inspection NrDate OpenedSICNAICSEstablishment Name
10773438608/27/199317310Lee Davis Electric, Inc.

Abstract: A JOURNEYMAN ELECTRICIAN WAS TROUBLESHOOTING A 480-VOLT CONTROL CIRCUIT FOR A CONVEYOR SYSTEM. THE CONVEYOR WAS USED TO RECEIVE AND PILE POTATOES AT A WAREHOUSE. THE ELECTRICIAN HAD REPLACED THREE MALFUNCTIONING COMPONENTS AND HAD RECONNECTED THE PLUG ON THE CONVEYOR'S POWER SUPPLY CABLE. HE THEN WENT TO THE CONTROL STATION AT THE RECEIVING END OF THE CONVEYOR AND GRABBED THE HAND GRIP THAT WAS PROVIDED TO AID EMPLOYEES CLIMBING ONTO THE CONTROL PLATFORM. HE WAS ELECTROCUTED AS HE TOUCHED THE HAND GRIP. (THE CONVEYOR, WHICH WAS MOUNTED COMPLETELY ON RUBBER TIRES, WAS ISOLATED FROM GROUND.) INVESTIGATION REVEALED THAT A GREEN-COLORED CONDUCTOR HAD BEEN USED AS A 277-VOLT CIRCUIT CONDUCTOR. AN UNSKILLED EMPLOYEE HAD ERRONEOUSLY CONNECTED THIS CONDUCTOR TO TWO GREEN EQUIPMENT GROUNDING CONDUCTORS WITH A WIRE NUT AS HE WAS REPLACING A DAMAGED JUNCTION BOX. THE EQUIPMENT GROUNDING CONDUCTORS WERE CONNECTED TO THE FRAME OF THE CONVEYOR. WHEN THE CONVEYOR WAS ENERGIZED, THIS GROUND FAULT ALSO ENERGIZED THE CONVEYOR'S FRAME.

Keywords: ELECTRICAL, E GI VII, ELECTROCUTED, GROUND FAULT, CONVEYOR, EQUIPMENT GROUNDING, ELECTRIC CONDUCTOR

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 107734386 Fatality Electric Shock Electricians

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close