Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 800060 - Three employees injured when chemical mixture ignites

Accident Summary Nr: 800060 -- Report ID: 0454510 -- Event Date: 03/23/1999
Inspection NrDate OpenedSICNAICSEstablishment Name
30177478203/24/199936950Fuji Photo Film, Inc.

Abstract: At approximately 9:00 a.m. on March 23, 1999, Employees #1 through#3 were starting the initial phase of a mixing operation. Employees #1 and #2 were reading the Standard Operating Procedure (SOP) while Employee #1 added the chemicals. The employees who were reading skipped two steps, which called for a nitrogen purge on the tank to reduce the oxygen level to below 4 percent. These steps were necessary because the last chemical to be added was a self-heating powder that oxidized rapidly in the presence of oxygen. When Employee #3 added the product in the presence of oxygen, a flash fire broke out and powder was blown from the vessel. This caused the overhead sprinklers to activate and the plant was evacuated. Employees #1 through #3 were transported to the hospital, where they were treated and released. The employer was cited for deficient operating procedures, deficient management of change procedures, and failure to have a written plan for employee evacuation.

Keywords: OXYGEN, DUST, WORK RULES, FIRE, INHALATION, CHEMICAL REACTION, POWDER, CHEMICAL, INATTENTION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 301774782 Non Hospitalized injury Other Mixing and blending machine operators
2 301774782 Non Hospitalized injury Other Mixing and blending machine operators
3 301774782 Non Hospitalized injury Other Mixing and blending machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close