Accident Summary Nr: 772749 - ELECTRIC SHOCK - GROUND FAULT IN ELECTRIC WASHER

Accident Summary Nr: 772749 -- Report ID: 0627700 -- Event Date: 04/30/1992
Inspection NrDate OpenedSICNAICSEstablishment Name
10749892505/01/199213890Briggett, Inc.

Abstract: AN EMPLOYEE HAD REPAIRED THE HIGH PRESSURE HOSE ON THE STINGER III POWER WASHER (SERIAL NO. 481-1016) HE HAD BEEN USING. AFTER HE COMPLETED THE REPAIR, HE TURNED THE UNIT ON TO CHECK THE HOSE AND TO WASH HIS TRACTOR. WHEN HE TOUCHED THE METAL WAND ON THE WASHER HANDLE, HE WAS ELECTROCUTED. THE WASHER WAS NOT GROUNDED BECAUSE OF AN IMPROPERLY WIRED ATTACHMENT PLUG ON THE WASHER'S POWER SUPPLY CORD. THE EQUIPMENT GROUNDING CONDUCTOR IN THE PLUG HAD WORKED LOOSE, AND AN APPARENT GROUND FAULT HAD ENERGIZED THE HANDLE THROUGH THE METAL REINFORCING OF THE HIGH PRESSURE HOSE. THE PANELBOARD FOR THE CIRCUIT WAS ALSO UNGROUNDED, AND THE GROUNDING ELECTRODE FOR THE SYSTEM WAS MISSING. (THE HIGH PRESSURE PUMP NEXT TO THE WASHER WAS LATER FOUND TO BE UNGROUNDED AS WELL.) ALL THIS EQUIPMENT WAS INSTALLED AND MAINTAINED BY A CONTRACTOR. THE ACCIDENT OCCURRED AT THE WASHING FACILITY AT THE COMPANY OFFICES.

Keywords: E GI V, ELECTRICAL, ELECTROCUTED, ATTACHMENT PLUG, GROUND FAULT, WET OPERATION, EQUIPMENT GROUNDING, SYSTEM GROUNDING, ELEC EQUIPMENT--MISC, WATER

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 107498925 Fatality Electric Shock Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close