Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 756148 - Two employees injured in water monitor manhole explosion

Accident Summary Nr: 756148 -- Report ID: 0855610 -- Event Date: 02/06/1993
Inspection NrDate OpenedSICNAICSEstablishment Name
11461543802/10/199316110Schmid Sand & Gravel Inc
Inspection NrDate OpenedSICNAICSEstablishment Name
11463261502/09/199391990Town Of Lyman

Abstract: Employees #1 and #2 were using a propane Weedburner to attempt to thaw-out a frozen water line in a water monitor manhole. The Weedburner was left unattended for several hours. When Employees #1 and #2 returned to the manhole, the Weedburner had lost its flame and the propane from the Weedburner tank had accumulated in the manhole. The employees believed that the weedburner flame had gone out because the propane tank was empty. A week later, Employees #1 and #2 returned to the water monitor manhole to attempt again to thaw out the frozen water line. One employee entered the manhole while the other one handed him the lit Weedburner wand. Employees #1 and #2 were struck by a flash fire, resulting from an accumulation of propane as in the manhole. Both employees received second-degree burns on their faces and hands for which they were hospitalized. Employees #1 and #2 did not perform atmospheric testing of the manhole before entering or using equipment.

Keywords: FLAMMABLE VAPORS, WORK RULES, EXPLOSION, PROPANE, MANHOLE, HAND, BURN, CONFINED SPACE, FIRE, FACE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 114615438 Hospitalized injury Burn/Scald(Heat) Construction laborers
2 114615438 Hospitalized injury Burn/Scald(Heat) Supervisors; handlers,equip-cleaners,laborers nec
3 114632615 Occupation Not Listed

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close