Accident Summary Nr: 722504 - EMPOYEE DIES DUE TO BURNS IN CONFINED SPACE

Accident Summary Nr: 722504 -- Report ID: 0521700 -- Event Date: 02/16/1985
Inspection NrDate OpenedSICNAICSEstablishment Name
124216302/19/198517960Phillips Getschou Co
Inspection NrDate OpenedSICNAICSEstablishment Name
133977902/19/198517110Phillips Getschow Co
Inspection NrDate OpenedSICNAICSEstablishment Name
124215502/19/198516290Commonwealth Edison Co
Inspection NrDate OpenedSICNAICSEstablishment Name
224051302/19/198516290Commonwealth Edison Co Station 20

Abstract: The employee entered a 24-in pipe to grind a bad weld. Oxygen was piped into the space to prevent asphyxiation. The atmosphere in the pipe became oxygen enriched and heat generated from the grinding caused the atmosphere to ignite. The employee scrambled out of the pipe. He sustained severe burns and died.

Keywords: BURN, OXYGEN, CONFINED SPACE, GRINDING WHEEL

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1242163 Fatality Burn/Scald(Heat) Occupation not reported
2 1339779 Occupation Not Listed
3 1242155 Occupation Not Listed
4 2240513 Occupation Not Listed

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.