Accident Report Detail
Accident Summary Nr: 68359.015 - One Employee is electrocuted, another receive an electric sh
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 998470.015 | 10/01/2014 | 238220 | Conservation Services, Inc. |
Abstract: At approximately 2:30 p.m. on October 1, 2014, Employee #1 was installing ductwork. He crawled into a tight space where gas pipes were running across the attic floor. A junction box with faulty wiring coming into contact with metal ductwork causing a neutral current to pass through someone in contact with both the ductwork and a ground path. The employee was electrocuted when coming into contact with the gas pipes and metal ductwork carrying a neutral current. The metallic ductwork was lying across a junction box that did not have a neutral conductor. The neutral wire was tied to a bare wire that was poorly attached to the junction box. Employee #2 tried to assist in pulling Employee #1 away from the workspace and touched the gas pipes for stability, and sustained an electrical shock.
| End Use | Project Type | Project Cost | Stories | Non-building Height | Fatality | ||
|---|---|---|---|---|---|---|---|
| Single family or duplex dwelling | Alteration or rehabilitation | Under $50,000 | 1 | 9 | X | ||
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation | Construction |
|---|---|---|---|---|---|---|---|
| 1 | 998470.015 | 55 | M | Fatality | Construction laborers | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Installing equipment (HVAC and other) Fatality Cause: |