Accident Summary Nr: 65453.015 - Employee cleaning a concrete truck is killed when a mixing d

Accident Summary Nr: 65453.015 -- Report ID: 0830300 -- Event Date: 07/15/2014
Inspection NrDate OpenedSICNAICSEstablishment Name
987213.01507/17/2014327320Associated Redi-Mix Concrete

Abstract: At 7:45 p.m. on July 15, 2014, an employee was working for a firm that made and provided ready-mix concrete. He was chipping concrete from the inside of a concrete truck's drum. As he was cleaning out the drum, he actuated the drum's rotating mechanism and he sustained bodily contusions and internal organ damage. The employee was killed.

Keywords: Caught In, Cleaning, Concrete Truck, Contusion, Drum, Lockout/Tagout, Machine Guarding, Rotating Parts

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 987213.015 49 M Fatality Truck drivers, heavy

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.