Accident Summary Nr: 605584 - SOLVENT SPILLED ON EMPLOYEE; RECEIVED CHEMICAL BURNS

Accident Summary Nr: 605584 -- Report ID: 0418100 -- Event Date: 06/11/1986
Inspection NrDate OpenedSICNAICSEstablishment Name
10036333206/11/198651690Alchem Chemical Company
Inspection NrDate OpenedSICNAICSEstablishment Name
10036334006/11/198628420Guardian Chemical Company

Abstract: EMPLOYEE #1 IS AN EMPLOYEE OF A CHEMICAL WHOLESALE DISTRIBUTION COMPANY. HE WAS DELIVERING APPROXIMATELY 1,000 GALLONS OF SHELL SOL 340 (MINERAL SPIRITS) TO A CHEMICAL MANUFACTURING COMPANY. HE CONNECTED THE HOSE FROM HIS TRUCK TO THE INLET VALVE OF THE 1,000 GALLON STORAGE TANK AND BEGAN PUMPING THE SOLVENT INTO THE TANK. AFTER A FEW MINUTES THE HOSE SUDDENLY RUPTURED AND THE END OF THE CYLINDRICAL, HORZONTAL STEEL STORAGE TANK BLEW OUT. THE EMPLOYEE'S BACK WAS TURNED WHEN THE RUPTURE OCCURRED. HE WAS SOAKED WITH THE LIQUID. NO FIRE OCCURRED. THE STORAGE TANK'S RELIEF VALVE WAS AN OPW 95-UT 2 INCH PRESSURE-VACUUM RELIEF VALVE. THE VALVE WAS ABOUT 20 YEARS OLD. THE TANK WAS APPROXIMATELY 25 YEARS OLD. IT APPEARS THAT THE RELIEF VALVE OPENED ONLY PARTIALLY. 500 TO 600 GALLONS OF SOLVENT WERE PUMPED INTO THE TANK BEFORE THE EXCESSIVE PRESSURE CAUSED THE BLOW OUT. EMPLOYEE #1 RECEIVED FIRST DEGREE BURNS ON HIS BACK.

Keywords: VALVE, CHEMICAL BURN, TANK, HOSE, RUPTURE, BACK, HIGH PRESSURE, SKIN, CHEMICAL

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 100363332 Hospitalized injury Burn(Chemical) Occupation not reported
2 100363340 Occupation Not Listed

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.