Accident Summary Nr: 604736 - ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU TRUCK

Accident Summary Nr: 604736 -- Report ID: 0418600 -- Event Date: 09/20/1991
Inspection NrDate OpenedSICNAICSEstablishment Name
10700769209/24/199124110Cherokee Timber Company, Inc.
Inspection NrDate OpenedSICNAICSEstablishment Name
10700768409/24/199124110Charles Lehman Harris

Abstract: AN EMPLOYEE OF A LOGGING COMPANY WAS UNTANGLING THE REAR, STEEL TIE-DOWN CABLE ON HIS 18-WHEEL TRUCK THAT WAS LOADED WITH LOGS. HE WAS GOING TO THROW THE CABLE OVER THE LOAD TO THE OTHER SIDE OF THE TRUCK IN ORDER TO SECURE THE LOGS. A COWORKER WENT TO THE FRONT TIE-DOWN CABLE TO ASSIST THE FIRST EMPLOYEE. THE COWORKER THREW THE FRONT CABLE OVER THE LOGS, AND IT CONTACTED AN OVERHEAD POWER LINE. THE FIRST EMPLOYEE, WHO WAS STILL HOLDING THE REAR CABLE, WAS ELECTROCUTED.

Keywords: OVERHEAD POWER LINE, ELECTRICAL, WIRE ROPE, ELECTROCUTED, E GI IA, TRUCK

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 107007692 Fatality Electric Shock Truck drivers, heavy
2 107007684 Occupation Not Listed

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.