Accident Summary Nr: 509455 - Two employees are injured when crane platform collapses
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 107238206 | 02/09/1994 | 1791 | 0 | Salt Creek Welding, Inc. |
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
| 107238198 | 02/09/1994 | 2951 | 0 | Idaho Asphalt Supply, Inc. |
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
| 107238214 | 02/09/1994 | 1791 | 0 | Tanco Engineering, Inc. |
Abstract: Two employees were lifted 26 ft on a personnel platform that was improperly rigged to a hydraulic crane. The rigging detached from the crane hook and the platform dropped to the ground. Employee #1 suffered a fractured back. Employee #2 suffered a lacerated cheek. The primary cause of the accident was the use of two chains with open throated hooks to sling the platform to the crane hook.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 107238206 | Hospitalized injury | Fracture | Occupation not reported | ||
| 2 | 107238198 | Non Hospitalized injury | Cut/Laceration | Occupation not reported | ||
| 3 | 107238214 | Occupation Not Listed |