Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 202721387 - Driver Strikes Two Highway Maintenance Workers, Kills One

Accident Summary Nr: 202721387 -- Report ID: 0352430 -- Event Date: 11/14/2013
Inspection NrDate OpenedSICNAICSEstablishment Name
31758299711/14/20131611237310Maryland Department Of Transportation

Abstract: On November 14, 2013, Employee #1, a 50-year-old male and Employee # 2, a 38-year-old male with Maryland Department of Transportation, were part of a highway maintenance crew, who were assigned to replace a highway speed limit sign alongside the I-695 Outer Loop, near the Putty Hill Avenue Overpass. The crew parked their work truck on the right shoulder beside lane #3; the vehicle was parked there for approximately twenty-five minutes prior to the incident. The truck was equipped with an amber light, mounted on top of the work truck that was on at the time of the incident. The work truck however, was not equipped with a traffic attenuator. There were no advance traffic warning signs or cone tapers, in place, to warn motorists of the shoulder closure, and no effort was made to divert traffic away from the shoulder closure, per MUTCD requirements. In addition, there was no shadow vehicle, equipped with a vehicle mounted impact attenuator, parked behind their work truck. Employee #1 and Employee #2 were standing on the shoulder at the rear of the work truck, with Employee #2, standing at the rear of the work truck, holding the base of the sign post. Suddenly, a motorist struck Employee #2, throwing him approximately 40 ft onto an earthen embankment, before striking Employee #1. Employee #1 was crushed to death between the rear of his work truck and the front bumper of the motorist's car. According to Maryland State Police, the driver was adjusting her driver's side mirror, which had been knocked loose by a mechanical brush at a carwash a short while before this incident occurred. Employee #2 was treated for musculoskeletal injuries in the emergency room, at the University of MD, Shock Trauma Center and released the same day.

Keywords: FRACTURE, HIGHWAY, VEHICLE, CONSTRUCTION, AUTOMOBILE, STRUCK BY, HIGHWAY SHOULDER
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Highway, road, street Maintenance or repair Under $50,000 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 317582997 Fatality Asphyxia Construction trades, n.e.c. Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Traffic protection
Fatality Cause: Crushed/run-over by highway vehicle
2 317582997 Non Hospitalized injury Bruise/Contus/Abras Construction trades, n.e.c. Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Traffic protection
Fatality Cause: Crushed/run-over by highway vehicle

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close