Accident Summary Nr: 202599528 - Seventeen Employees Are Exposed to Chlorine Dioxide

Accident Summary Nr: 202599528 -- Report ID: 0950612 -- Event Date: 09/15/2009
Inspection NrDate OpenedSICNAICSEstablishment Name
31348047709/17/20090723115114Earthbound Farm Holdings

Abstract: On September 15, 2009, the ER was conducting a start-up of a new chlorine dioxide disinfectant for food processing, when the concentration was ramped up. The residual organics reacted with the chlorine dioxide stream and created chlormines; a probable effect of under chlorination. This water mist, which was irritating, was breathed in by the employee. Seventeen employees were treated and released by the local hospitals.

Keywords: LUNG, INHALATION, CHLORINE DIOXIDE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 313480477 Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.