Accident Report Detail
Accident Summary Nr: 202447876 - Employee Amputates Fingertip in Hydro-Pneumatic Press
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 310601166 | 11/21/2007 | 3714 | 336399 | Hayden Automotive |
Abstract: At 1:20 p.m. on October 29, 2007, Employee #1, a set-up operator employed by Hayden Automotive in Corona, California, was making an adjustment to a Schmidt Technology Hydro-Pneumatic Press CLH 186, Model Number 74- 5784-03, Serial Number 2-0009. The press cycled and caught Employee #1's index fingertip on his left hand. A coworker drove Employee #1 to the Comp Clinic in Corona, California, for emergency treatment. He was referred to an orthopedic specialist in Corona. The medical report listed an amputation (traumatic-partial) complicated of the left second digit finger.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 310601166 | Non Hospitalized injury | Amputation | Production inspectors, checkers and examiners |
Translate