Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 201954104 - Four Employees Injured When Exposed to Arsine Gas

Accident Summary Nr: 201954104 -- Report ID: 0522000 -- Event Date: 01/21/2005
Inspection NrDate OpenedSICNAICSEstablishment Name
30851028801/24/20053823334513Powell Water Manufacturing Corporation
Inspection NrDate OpenedSICNAICSEstablishment Name
30851027001/24/20053674334413Sumco Phoenix Corporation

Abstract: During the afternoon of January 21, 2005, four employees were working in a room containing equipment that was designed to use an electro-coagulation system to remove arsenic from process water. Adjustments to the system were being implemented to increase the speed of arsenic coagulation. By the following morning all four workers were passing urine which was blood red in color, and all four had been admitted into hospitals. The inhalation of Arsine gas caused the symptoms and adverse medical consequences which have been exhibited by these four employees. Excessive levels of Arsenic have been found in their systems. The leading theory concerning the mechanism of generation of Arsine gas was that nascent hydrogen could form when an electric current flowed through an aqueous solution containing substantial concentrations of electrolytes. This hydrogen could react with the arsenic present in this solution to form arsine gas. The workers who suffered the most severe medical consequences spent prolonged periods of time on an elevated platform, looking directly down into the Electro-Coagulation Unit, and making observations as various adjustments were made to the process, such as changes in the amperage of electric current flowing through the process liquid which contained dissolved compounds of arsenic. The use of sulfuric acid to periodically clean the unit and the iron plates which it contained might also have been a contributing factor. Two of the four hospitalized workers displayed little or no functioning of the kidneys and underwent dialysis.

Keywords: INHALATION, AIR CONTAMINATION, GAS, CHEMICAL VAPOR, KIDNEY, POISONING, CHEMICAL

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 308510288 Hospitalized injury Poisoning(Systemic) Occupation not reported
2 308510288 Hospitalized injury Poisoning(Systemic) Occupation not reported
3 308510270 Hospitalized injury Poisoning(Systemic) Occupation not reported
4 308510270 Hospitalized injury Poisoning(Systemic) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.