Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 201380177 - electric shock - ground fault in sump pump

Accident Summary Nr: 201380177 -- Report ID: 0214500 -- Event Date: 05/20/1998
Inspection NrDate OpenedSICNAICSEstablishment Name
30195111705/21/199844930Grand Cove Marina Inc.

Abstract: An employee for a marina was using a Simer Geyser Submersible Utility Pump to pump out the bilge of a work barge. The pump was equipped with float switch and was connected via an extension cord to a dockside 125-volt receptacle outlet. The receptacle was improperly wired with the line and neutral connections reversed. Also, the cord set had been repaired and the receptacle cord cap was missing the equipment grounding prong. The employee was electrocuted when he stepped into the water-filled bilge of the barge and contacted a grounded surface. (The employee also had second-degree electrical burns on his back and above his right eye.)

Keywords: RECEPTACLE, ELECTRICAL, REVERSE POLARITY, CORD SET, E GI VII, ELECTROCUTED, GROUND FAULT, EQUIPMENT GROUNDING, PUMP

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 301951117 Fatality Electric Shock Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.