Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 201260247 - THREE EMPLOYEES EXPOSED TO HYDROFLUORIC ACID

Accident Summary Nr: 201260247 -- Report ID: 0524200 -- Event Date: 12/08/1997
Inspection NrDate OpenedSICNAICSEstablishment Name
30095525912/09/199736710Zenith Electronics Corp.

Abstract: On December 8, 1997 a leak developed in a hydrofluoric acid check valve, spilling approximately 25-35 gallons of 70 percent hydrofluoric acid in the basement of the Zenith Electronics-Rauland Plant in Melrose Park, IL. A number of employees working in the basement area were exposed to acid vapors to the extent that an emergency evacuation was initiated at the plant. The plant critical processes and pipes were shut down shortly after the evacuation. Employees #1, #2, and #3 were hospitalized after receiving doses of inhalation high enough to require hospitalization. Two employees were kept 24 hours for observation and then released. One employee was kept for 43 hours and then released. Employees #1, #2, and #3 were interviewed after coming back to work at Zenith. All were doing fine. The plant was closed down for three days and a subcontractor, Clean Harbor, was contracted to clean up the initial spill. Zenith maintenance personnel changed the defective valve. The activity of the contracted spill response team on site was observed from outside the regulated area the day after the incident. It appeared to the CSHO, after questioning the on-scene incident commander of Clean Harbor, the clean-up activities, PPE, and methodologies, that these were executed following federal regulations and using good judgment. The CSHO did not initiate an inspection of Clean Harbor.

Keywords: LEAK, ASPHYXIATED, VAPOR, HYDROFLUORIC ACID, INHALATION, SHUT-OFF VALVE, VALVE, PIPE, SPILL, EVACUATION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 300955259 Hospitalized injury Asphyxia Stock and inventory clerks
2 300955259 Hospitalized injury Asphyxia Electricians
3 300955259 Hospitalized injury Asphyxia Laborers, except construction

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close