Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 201200656 - Employee caught in pulley of a manlift

Accident Summary Nr: 201200656 -- Report ID: 1054114 -- Event Date: 09/17/1999
Inspection NrDate OpenedSICNAICSEstablishment Name
30272767209/20/199907230Grain Millers Inc

Abstract: Employee #1 was riding a manlift when he failed to get off and was carried into the top pulley at the ninth floor level. His rigid body negated three guards designed to stop the machine, allowing him to cross over the top. His left arm became tangled in the pulley guard and was badly lacerated as the remaining steps drove it into the pulley guide. He was hospitalized.

Keywords: ELEVATOR GATE, GUARD, CAUGHT BY, LACERATION, ARM, NIP POINT, PULLEY, ELEVATOR, MILL--PLANT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 302727672 Hospitalized injury Cut/Laceration Miscelaneous food preparation occupations

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.