Accident Summary Nr: 201180015 - Burn - Electric Arc Ignited Spray-applied Adhesive

Accident Summary Nr: 201180015 -- Report ID: 0950611 -- Event Date: 07/22/1998
Inspection NrDate OpenedSICNAICSEstablishment Name
12549039107/27/199834440Yum'S Mechanical

Abstract: An employee working for a heating and ventilation contractor sprayed a coating of a flammable adhesive containing methylene chloride to the inner surface of a sheet metal duct section. The employee then positioned a piece of precut fiberglass insulation against the glued surface and allowed it to set for approximately 5 minutes. He then spot welded retention pins through the fiberglass insulation and onto the sheet metal using pinspot-type welded insulation fasteners. The electric arc generated by the spot welder ignited the flammable vapors from the adhesive, which were trapped in the air spaces in the insulation. The ensuing flash fire burned the employee's face, neck, right ear, and inner right forearm. He was hospitalized for 5 days. (The spray application of the flammable adhesive and the spot welding were conducted in a general shop area, not a well ventilated work station.)

Keywords: BURN, ELECTRIC ARC, SPOT WELDING, E GI III, ELECTRICAL, FLAMMABLE LIQUID, GLUE, WELDER, WELDING, THERMAL INSULATION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 125490391 Hospitalized injury Burn/Scald(Heat) Sheet metal workers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close