Accident Report Detail
Accident Summary Nr: 201113461 - Employee burned when hoist mechanism contacts power lines
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 120309653 | 09/08/2001 | 1542 | 0 | Sme Construction |
Abstract: At approximately 11:00 a.m. on September 9, 2001, Employee #1, of CHP Steel, and a coworker of the general contractor, SME Construction, Inc., were working on the RCC Channel Project. The coworker, a crane operator, was hoisting a spreader bar with a steel mat attached, that was being guided by Employee #1 for placement on a wooden channel structure under construction. Employee #1 was using a wire to guide the mat when the spreader bar hoisting equipment contacted 16-kilovolt power lines. Employee #1 received an electric shock, suffering third-degree burns to his right hand, his right and left legs, and his stomach. The employer was cited for an accident-related violation, serious, of T8CCR 2946(b)(3), concerning provisions for preventing accidents due to proximity to overhead lines.
| End Use | Project Type | Project Cost | Stories | Non-building Height | Fatality | ||
|---|---|---|---|---|---|---|---|
| Shoreline development, dam, reservoir | New project or new addition | $50,000 to $250,000 | 16 | ||||
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation | Construction |
|---|---|---|---|---|---|---|---|
| 1 | 120309653 | Hospitalized injury | Electric Shock | Structural metal workers | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Emplacing reinforcing steel Fatality Cause: Electric shock, other and unknown cause |