| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 120309976 | 04/25/2001 | 1761 | 0 | Pacific Island Roofing Systems |
Abstract: Employee #1 died when he fell 20 to 24 feet from an extension ladder while putting on an ornamental chimney cover on the chimney stack. The height of the chimney stack measured approximately 24 feet. Employee #1 used a 12-foot aluminum extension ladder. The ladder measured 24 feet long at the time of inspection. Based on the position where the ladder landed, the feet of the ladder were positioned 3 to 5 feet away from the vertical sides of the chimney stack, which resulted in an acute pitch angle. Employee #1 failed to secure, block, or tie the ladder to prevent displacement. Employee #1 fell 20 to 24 feet to his death.
| End Use | Project Type | Project Cost | Stories | Non-building Height | Fatality | ||
|---|---|---|---|---|---|---|---|
| Single family or duplex dwelling | Alteration or rehabilitation | Under $50,000 | 2 | X | |||
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation | Construction |
|---|---|---|---|---|---|---|---|
| 1 | 120309976 | Fatality | Fracture | Roofers | Distance of Fall: feet Worker Height Above Ground/Floor: 24 feet Cause: Roofing Fatality Cause: Fall from/with ladder |