Accident Summary Nr: 201080173 - Two employees suffer carbon monoxide poisoning

Accident Summary Nr: 201080173 -- Report ID: 0950625 -- Event Date: 12/04/1996
Inspection NrDate OpenedSICNAICSEstablishment Name
12577628601/30/199707230Ito Packing Co Inc

Abstract: On December 4, 1996, Employees #1 and #2 were consolidating fruit in the refrigerated storage area at a fruit packing facility. It was a large packing house with a year around crew, where fruit was sorted, stored, and packed according to size and quality, and then shipped. At the time of the incident, Employees #1 and #2 were being supervised on an in-and-out basis. Other workers had been using propane-powered forklifts earlier that morning. One of the forklifts, #125, reportedly was not equipped with a catalytic converter and had been emitting nauseous exhaust fumes. Employees #1 and #2 became ill and were diagnosed as suffering from carbon monoxide poisoning by the treating physician. Industrial health care reported the carboxyhemoglobins for both Employees #1 and #2 to be over 32. Direct reading equipment showed elevated levels of carbon monoxide, in excess of 200 ppm, in sheds #1 and #2, which were packing and sorting areas. An effective exhaust ventilation system was available for use in these rooms but was not turned on to conserve energy. Following the incident, one of the forklift units was removed from indoor use. The employer also said it would replace the propane forklifts with electric ones for use indoors whenever possible, and it agreed to keep the ventilation system on in these areas whenever workers were present. The employer was cited for a violation of T8CCR 3203(a)(7), serious, because employees had not been trained about the hazards and signs associated with carbon monoxide exposure; and a violation of T8CCR 5155(e)(1), serious, because the employer should have been aware of the potential for carbon monoxide in areas where propane-powered forklifts were used indoors, and monitored these areas accordingly.

Keywords: VENTILATION, WORK RULES, INHALATION, INDUSTRIAL TRUCK, EXHAUST FUMES, CARBOXYHEMOGLOBIN, CHEMICAL VAPOR, POISONING, OVEREXPOSURE, CARBON MONOXIDE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 125776286 Hospitalized injury Poisoning(Systemic) Occupation not reported
2 125776286 Hospitalized injury Poisoning(Systemic) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.