Accident Report Detail
Accident Summary Nr: 201057114 - Employee's thumb amputated in tortilla oven
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 126082114 | 01/06/2003 | 2051 | 311830 | Gonzalo Santana Dba La Unica Tortilleria |
Abstract: At approximately 7:00 a.m. on November 25, 2002, Employee #1 was assisting a coworker replacing a cutting wire in a tortilla oven. While Employee #1 was holding the wire between two sprockets on the east side of oven, the coworker was tightening wires from the west side. After Employee #1 pushed the wire into place on a holding pin with his left hand, the coworker turned on the machine and the sprockets severed Employee #1's left thumb. The causes of the accident were failure to deenergize the machine during service, and failure to use extension tools.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 126082114 | Non Hospitalized injury | Amputation | Machine operators, not specified |