Accident Summary Nr: 201052297 - Employee Is Killed When Oxygen Flow Is Compromised

Accident Summary Nr: 201052297 -- Report ID: 0950642 -- Event Date: 03/17/1999
Inspection NrDate OpenedSICNAICSEstablishment Name
12606677803/17/199937280Northrup Grumman Corp

Abstract: At approximately 7:30 a.m. on March 17, 1999, Employee #1, an aerospace engineer, who had been reassigned to complete stripping of a stealth leading edge airplane wing, was using wheat starch abrasive blasting, inside of a spray paint booth. He was wearing a supplied air blasting hood, which delivered filtered plant air. He had been working on this project intermittently over the past 10 days. A company plumber, who was working on Autoclave Number 1 a few hundred feet away, accidentally turned on the ball valve, causing nitrogen to be introduced into the breathing air line at the wheat starch booth. Employee #1 was found by a coworker lying on the floor, with blue-purple lips and no vital signs, with the equipment still running. CPR was started, and emergency medical services called. He was transported to a nearby hospital, where he was pronounced dead.

Keywords: AIRCRAFT, BLASTING, ASPHYXIATED, VAPOR, WING, PPE, INHALATION, GAS, NITROGEN, VALVE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 126066778 Fatality Asphyxia Aerospace engineers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close