Accident Summary Nr: 200841914 - Employee Dies after Being Struck in Head by Pipe

Accident Summary Nr: 200841914 -- Report ID: 0524530 -- Event Date: 08/23/2010
Inspection NrDate OpenedSICNAICSEstablishment Name
31301669308/24/20101799238990Foltz Welding, Ltd.

Abstract: At approximately 5:00 p.m. on August 23, 2010, Employee #1, a pipefitter, was working with a crew of five pipefitters and one operator, moving a long section of 8-inch high density polyethylene (HDPE) pipe into position onto a McElroy Manufacturing Fusion Machine, MN 6-12. The crew was staging the part to weld a flange and Chicago fitting onto the end of the 8-inch HDPE the following day. This was being done to provide water for a hydrotest of fabricated process piping prior to being placed into service per applicable API mechanical integrity standards. The 8-inch HDPE pipe was being run from a retention pond several hundred yards to the north, and had previously been used to run water elsewhere on the new construction project. There was standing water in the charged line. The crew cut the 8-inch HDPE pipe and rigged a 12-ft endless synthetic web sling to the bucket of a Caterpillar 346 CL. The cab of the Caterpillar 346 CL was positioned 21 feet from the McElroy fusion machine. As the Caterpillar operator began to drag the long section of 8-inch HDPE into position, his primary attention was focused on watching the movement of the pipe on the ground. As the forward section was elevated by the endless sling, rigged 10-ft to 15-ft from the end of the pipe in a choker hitch, the sling slid out of the wet/smooth surface of the 8-inch HDPE pipe. The pipe struck Employee #1 in the head with such force that it broke the suspension of his Bullard MN S-71 protective helmet. He died as a result of the blow to his head.

Keywords: HEAD, HARD HAT, HOISTING MECHANISM, PPE, PIPE, STRUCK BY, SLING, FALLING OBJECT
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Tower, tank, storage elevator New project or new addition $1,000,000 to $5,000,000 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 313016693 Fatality Bruise/Contus/Abras Plumbers, pipefitters and steamfitters Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Installing plumbing, lighting fixtures
Fatality Cause: Lifting operations

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.