Accident Summary Nr: 200630754 - Employee died from exposure to chemical

Accident Summary Nr: 200630754 -- Report ID: 0316400 -- Event Date: 04/18/2002
Inspection NrDate OpenedSICNAICSEstablishment Name
30046311405/03/200250820Morgantown National Supply, Inc.

Abstract: Employee #1, a machinist, was instructed to clean machinery in the shop. A material known as Bulkie FW concentrate was dispensed from an unlabeled drum into a coffee can. Using a rag and wearing safety glasses but no gloves, the employee wiped the liquid cleaner onto the machinery, applying it at full strength. The material contains tetrapotassium pyrophosphate and sodium metasilicate which are corrosive materials. The material splashed onto the employee's face. He washed the product from his face and safety glasses and continued using the product for the next 2 and a half days. After experiencing a dry cough and shortness of breath, he received medical attention and was told that his lungs appeared to be chemically burned. The employee was sent to a pulmonary specialist, hospitalized, placed on oxygen, and evaluated for a lung transplant. The diagnosis was idiopathic pulmonary fibrosis (IPF). He later died from his injuries.

Keywords: LUNG, CLEANING, CHEMICAL VAPOR, OVEREXPOSURE, CHEMICAL

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 300463114 Fatality Burn(Chemical) Machinists

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close