Return to Accident Search Results
Accident Report Detail
Accident Summary Nr: 200612026 - Employees Are Injured in Rack Collapse
Accident Summary Nr: 200612026 -- Report ID: 0111700 -- Event Date: 11/15/2005
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
| 306952847 | 11/15/2005 | 1711 | 238220 | Ouellette Plumbing & Heating Corp. |
Abstract:
On November 15, 2005, Employees #1 through #6 were loading a Unistrut rack with copper pipe of varying sizes. The rack collapsed Employee #1, who was then hospitalized with fractures. Employees #2 trough #6 sustained various injuries during the rescue of Employee #1. The rack had been improperly constructed in three ways: (1) single through-bolts were used to assemble some of the horizontal and vertical members within the rack, instead of "T" or gusset connections, as specified by the rack component manufacturer; using the single bolts allowed the connections to rotate around the bolt, (2) the horizontal braces were connected with single bolts, instead of "T" or gusset connections, as specified by the rack component manufacturer; using the single bolts allowed the connections to rotate around the bolt, and (3) diagonal braces were not used to stabilize the frames.
Keywords:
COLLAPSE, EQUIPMENT FAILURE, BOLT, BRACE, PIPE, STORAGE RACK, STRUCK BY, STORAGE AREA
Accident Details
| End Use |
Project Type |
Project Cost |
Stories |
Non-building Height |
Fatality |
| Other building |
New project or new addition |
$5,000,000 to $20,000,000 |
4 |
|
|
Employee Details
| Employee # |
Inspection Nr |
Age |
Sex |
Degree of Injury |
Nature of Injury |
Occupation |
| 1 |
306952847 |
|
|
Non Hospitalized injury |
Bruise/Contus/Abras |
Occupation not reported |
| 2 |
306952847 |
|
|
Non Hospitalized injury |
Strain/Sprain |
Occupation not reported |
| 3 |
306952847 |
|
|
Non Hospitalized injury |
Bruise/Contus/Abras |
Occupation not reported |
| 4 |
306952847 |
|
|
Non Hospitalized injury |
Strain/Sprain |
Occupation not reported |
| 5 |
306952847 |
|
|
Hospitalized injury |
Fracture |
Occupation not reported |
| 6 |
306952847 |
|
|
Non Hospitalized injury |
Bruise/Contus/Abras |
Occupation not reported |