Accident Summary Nr: 200600351 - Employee killed when caught in die casting machine

Accident Summary Nr: 200600351 -- Report ID: 0625400 -- Event Date: 05/17/1998
Inspection NrDate OpenedSICNAICSEstablishment Name
30043683905/18/199833630Dynacast Mfg Inc

Abstract: Employee #1 was operating a Buhler 400-ton die casting machine in automatic mode. He was placing inserts into the die when the die closed on him, severely crushing his head and arm. Employee #1 was killed. The internal safety trip was missing from the machine.

Keywords: HEAD, DIE SAFETY DEVICE, WORK RULES, INTERLOCK, CAUGHT BETWEEN, CRUSHED, ARM, DIE CASTING MACHINE, MACHINE--MISC

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 300436839 Fatality Amputation Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.