Accident Summary Nr: 200232338 - Employee Is Killed When Trench Caves In

Accident Summary Nr: 200232338 -- Report ID: 1032500 -- Event Date: 09/16/2009
Inspection NrDate OpenedSICNAICSEstablishment Name
31335001909/16/20091623237110Bowman'S Inc. Of Mountain Home

Abstract: On September 16, 2009, Employee #1 was laying pipe in a 9 ft deep trench. He was connecting two sections of 12 in. diameter by 14 feet long pipe. The pipe end was lubed and Employee #1 left the protection of the trench shield to push the pipes together from the end not being connected. The first attempt to connect the pipes from a standing position was unsuccessful. Employee #1 sat down to kick and push the pipes together using his legs. Immediately after he pushed the pipes together, a cave-in occurred from the upper portion of the trench wall that was near an existing gas supply line. Employee #1 was buried and killed.

Keywords: TRENCH BOX, TRENCH, PIPE, BURIED, CAVE-IN
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Pipeline New project or new addition $50,000 to $250,000 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 313350019 Fatality Asphyxia Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Trenching, installing pipe
Fatality Cause: Trench collapse

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close