Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200170108 - ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU BOOM

Accident Summary Nr: 200170108 -- Report ID: 0257260 -- Event Date: 11/12/1999
Inspection NrDate OpenedSICNAICSEstablishment Name
30014385611/15/199975380Municipio Bayamon- Dept. Proteccion Ambiental

Abstract: An employee was working at the controls of a boom mounted on a Ford truck. He operated the controls to raise the boom instead of lowering it, and the boom contacted an overhead power line. The employee was electrocuted.

Keywords: OVERHEAD POWER LINE, ELECTRICAL, BOOM, CRANE BOOM, ELECTROCUTED, E GI IA, CRANE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 300143856 Fatality Electric Shock Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close