Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170727366 - EMPLOYEE SUFFERS BURNS WHEN PROPANE TANK IGNITES

Accident Summary Nr: 170727366 -- Report ID: 0950615 -- Event Date: 09/25/1993
Inspection NrDate OpenedSICNAICSEstablishment Name
11973237810/04/199379990Suburban Propane

Abstract: AT 6:00 A.M. ON SEPTEMBER 25TH, EMPLOYEE #1, A GROUND CREWPERSON FOR ABOVE THE WEST HOT AIR BALLOON, WAS PREPARING TO REFILL PROPANE TANKS IN A BARNES AX8 HOT AIR BALLOON SO IT COULD BE FLOWN THAT MORNING. HE WAS AT SUBURBAN PROPANE IN YOUNTVILLE, CALIFORNIA, WHERE HIS COMPANY HAD A SELF-SERVE AGREEMENT TO FILL TANKS. NORMALLY, EMPLOYEE #1 USED THE COMPUTERIZED CARDLOCK STATION, BUT IT WAS INOPERATIVE AND ALL FILLING HAD TO BE DONE FROM A NOZZLE ON THE OUTSIDE OF THE FILL BUILDING. EMPLOYEE #1 STARTED TO RIG THE FUEL HOSES TO REFUEL BY TAKING THE MAIN HOSES OFF THE BURNERS TO ATTACH THEM TO A "T" ADAPTOR, WHICH HE WOULD CONNECT TO SUBURBAN'S FILL NOZZLE AND HOSE. EMPLOYEE #1 FOUND HE HAD NO T-ADAPTOR ON HIS TRUCK, SO HE BORROWED ONE FROM ANOTHER CUSTOMER AND RETURNED TO HIS CHASE TRUCK TO FINISH THE HOOKUP, MAKING SURE ALL CONNECTIONS WERE TIGHT. THE NEXT STEP WHEN FILLING WAS TO MANUALLY TURN ON THE ELECTRIC PROPANE PUMP USING A SWITCH INSIDE THE FILL BUILDING. ANOTHER CUSTOMER IN THE BUILDING OFFERED TO TURN ON THE PUMP SWITCH. BEFORE TURNING IT ON, SHE ASKED EMPLOYEE #1 IF EVERYTHING WAS READY TO GO; HE SAID EVERYTHING WAS OK. THE CUSTOMER TURNED ON THE PUMP SWITCH AND LEFT THE FILL BUILDING. EMPLOYEE #1 STARTED REFUELING BY FILLING THE RIGHT FRONT CYLINDER. HE OPENED THE 10 PERCENT VALVE, WHICH VENTS THE TANK, THEN OPENED THE MAIN TANK VALVE AND THE NOZZLE VALVE TO FILL THE TANK. WHEN THE FIRST TANK WAS NEARLY FULL (WHEN FULL, THE 10 PERCENT VALVE STOPS VENTING VAPOR AND STARTS VENTING LIQUID PROPANE), EMPLOYEE #1 TURNED AROUND IN THE TRUCK BED TO FUEL THE TWO TANKS IN THE LEFT REAR CORNER. AS HE TURNED AND BENT OVER TO OPEN THE 10 PERCENT AND FILL VALVES, HE FELT HEAT ON HIS LEGS. EMPLOYEE #1 TURNED BACK TO DETERMINE THE SOURCE OF THE HEAT AND SAW THE PROPANE VENTING FROM THE 10 PERCENT VALVE. THE PROPANE IGNITED, FLASHING IN HIS FACE AND SINGEING HIS FACE AND HAIR. HE PULLED BACK FROM THE FLAME AND ROLLED OUT OF THE TRUCK. HE THEN RAN AWAY FROM THE TRUCK, OBSERVING THE GONDOLA BASKET ON FIRE. EMPLOYEE #1 SUFFERED FIRST-DEGREE BURNS ON HIS FACE, AS WELL AS FIRST- AND SECOND-DEGREE BURNS ON HIS LEGS. HE WAS WEARING A LEATHER JACKET AND LEATHER GLOVES WHILE REFUELING. BECAUSE HE WORE NYLON SHORTS, HOWEVER, HIS LEGS WERE NOT PROTECTED AND WERE BURNED MORE SEVERELY. WITNESSES HEARD THE SOUND OF THE INITIAL EXPLOSION AND, WHEN THEY FIRST OBSERVED THE SCENE, SAW THAT THE FIRE WAS CONFINED TO THE GONDOLA. THUS, IT IS REASONABLE TO ASSUME THAT THE INITIAL POINT OF IGNITION WAS INSIDE OF THE GONDOLA. EMPLOYEE #1 STATED THAT NO CONNECTIONS WERE LEAKING, HE WAS NOT SMOKING, THE TRUCK'S ENGINE HAD BEEN SHUT OFF EARLIER, AND HE HAD NOT USED ANY TOOLS AFTER THE FUEL VALVE HAD BEEN TURNED ON. IT IS NOT POSSIBLE TO DETERMINE THE ACTUAL SOURCE OF IGNITION FROM THE PHYSICAL EVIDENCE AND WITNESS STATEMENTS. A POSSIBLE SOURCE THAT CANNOT BE ELIMINATED IS A STATIC ELECTRICITY SPARK FROM EMPLOYEE #1'S NYLON SHORTS TO A GROUNDED SURFACE IN THE GONDOLA, POSSIBLY CREATED AS EMPLOYEE #1 TURNED AND BENT OVER TO FILL THE TWO LEFT REAR TANKS. NO ACCIDENT-RELATED VIOLATIONS WERE FOUND. THE EMPLOYER WAS CITED FOR NOT HAVING ANY DOCUMENTATION OF QUALIFIED LP GAS TRANSFER ATTENDANT TRAINING AS REQUIRED BY 8CCR 472(E)(1) AND FOR NOT HAVING A WRITTEN HAZARD COMMUNICATION PROGRAM (8CCR 5194(E)). WITNESSES AS WELL AS FORMER AND PRESENT EMPLOYERS ALL CLASSIFIED EMPLOYEE #1 AS A VERY EXPERIENCED BALLOON GROUND CREWPERSON, WHO WAS DOING EVERYTHING AS IT WAS SUPPOSED TO BE DONE DURING REFUELING AT THE TIME OF THE ACCIDENT.

Keywords: BURN, HAIR, OPEN VALVE, GAS, EXPLOSION, VALVE, PROPANE, FACE, TANK

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 119732378 Non Hospitalized injury Burn/Scald(Heat) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close