Accident Summary Nr: 170194138 - ELECTRIC SHOCK - GROUND FAULT IN MOBILE HOME WIRING

Accident Summary Nr: 170194138 -- Report ID: 0950633 -- Event Date: 09/26/1990
Inspection NrDate OpenedSICNAICSEstablishment Name
11203850007/27/199017310Don Hegge Electric

Abstract: An electrical contractor had been hired by a mobile home owner to determine why the owner was receiving electric shocks from the outside piping. An electrician with about 4 years of experience was assigned the job. The employee determined that the trailer frame and the piping were energized at 120 volts. He crawled under the trailer to look for faulty wiring. As he was crawling under the trailer, he passed over a copper refrigerant line that was also energized. The employee was electrocuted. An inspection of the main panelboard discovered that the main bonding jumper was missing.

Keywords: E GI IV, ELECTRICAL, ELECTRICIAN, ELECTROCUTED, ELECTRICAL WORK, MOBILE HOME, LOCKOUT, GROUND FAULT, EQUIPMENT GROUNDING, SYSTEM GROUNDING

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 112038500 Fatality Electric Shock Electricians

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close