Accident Summary Nr: 170133482 - ELECTRIC SHOCK - DIRECT CONTACT WITH OVERHEAD LINE

Accident Summary Nr: 170133482 -- Report ID: 1054118 -- Event Date: 08/31/1993
Inspection NrDate OpenedSICNAICSEstablishment Name
12375104209/01/199315210Ekman Enterprises Inc

Abstract: Two roofers were in an aerial lift, working on the edge of a roof at an apartment building. As they were working, the roofer who was operating the aerial lift contacted a 12-kilovolt overhead power line. This energized the aerial lift's metal platform. One of the employees was electrocuted; the other received an electric shock and was seriously injured. The injured employee was hospitalized.

Keywords: E GI III, OVERHEAD POWER LINE, ELECTRICAL, ELECTROCUTED, ROOFER, ELECTRIC SHOCK, UNTRAINED, AERIAL LIFT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 123751042 Fatality Electric Shock Roofers
2 123751042 Hospitalized injury Electric Shock Roofers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.