Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170084362 - One employee dies, two injured by asphyxia in yeast vat

Accident Summary Nr: 170084362 -- Report ID: 0625400 -- Event Date: 02/11/1996
Inspection NrDate OpenedSICNAICSEstablishment Name
12359147102/12/199620510Richter'S Bakery Of San Antonio Inc.

Abstract: Employee #1 entered an approximately 5 ft by 8 ft stainless steel vat to retrieve a small object. After searching for Employee #1 for approximately 30 minutes, Employee #2 entered the vat to retrieve him but became ill and fainted. Employee #3 then went into the vat to retrieve Employees #1 and #2, but he became dizzy and was pulled out by coworkers. Employee #2 was retrieved by rescue services and both he and Employee #3 were hospitalized for asphyxia. Employee #1 had already died of asphyxia by the time he was pulled out of the vat. The vat was being used to brew yeast for a bakery. Carbon dioxide is given off and oxygen is depleted during the fermentation process.

Keywords: OXYGEN DEFICIENCY, UNCONSCIOUSNESS, ASPHYXIATED, CONFINED SPACE, WORK RULES, INHALATION, SCBA, DIZZINESS, CARBON DIOXIDE, OVEREXPOSURE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 123591471 Fatality Asphyxia Occupation not reported
2 123591471 Hospitalized injury Asphyxia Occupation not reported
3 123591471 Hospitalized injury Asphyxia Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close