Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170072995 - Eight employees ill from carbon monoxide exhaust

Accident Summary Nr: 170072995 -- Report ID: 0453710 -- Event Date: 09/17/1991
Inspection NrDate OpenedSICNAICSEstablishment Name
1855511009/19/199123390Sportswear Express, Inc.

Abstract: A propane-powered forklift was used to unload cut fabric from a truck trailer. Before the fabric could be unloaded, other goods in the trailer had to be moved and then reloaded in order to access the fabric. This added time to unload resulted in the forklift running longer than usual. Sewing machine operators in the adjacent area were exposed to propane from a leaking fuel line and carbon monoxide from the exhaust. Employees #1 through #8 developed severe headaches and one employee passed out. Emergency medical services were called and the building was evacuated. Employees #1 through #8 were taken to the hospital, treated with oxygen and Tylenol, and released. Six of the injured employees returned to work the next day; the remaining two returned one day later. Tests of the forklift exhaust showed high levels of carbon monoxide due to improper fuel-to-oxygen ratio.

Keywords: LEAK, UNCONSCIOUSNESS, HEADACHE, INDUSTRIAL TRUCK, EXHAUST FUMES, OFF LOADING, PROPANE, OVEREXPOSURE, CARBON MONOXIDE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 18555110 Non Hospitalized injury Poisoning(Systemic) Occupation not reported
2 18555110 Non Hospitalized injury Poisoning(Systemic) Occupation not reported
3 18555110 Non Hospitalized injury Poisoning(Systemic) Occupation not reported
4 18555110 Non Hospitalized injury Poisoning(Systemic) Occupation not reported
5 18555110 Non Hospitalized injury Poisoning(Systemic) Occupation not reported
6 18555110 Non Hospitalized injury Poisoning(Systemic) Occupation not reported
7 18555110 Non Hospitalized injury Poisoning(Systemic) Occupation not reported
8 18555110 Non Hospitalized injury Poisoning(Systemic) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close