Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 145933.015 - Employee is killed when caught in freezer

Accident Summary Nr: 145933.015 -- Report ID: 0627100 -- Event Date: 04/30/2022
Inspection NrDate OpenedSICNAICSEstablishment Name
1592906.01504/30/2022424490Sage V Foods, Llc

Abstract: At 6:45 p.m. on April 30, 2022, an employee was in the blast freezer (Serial Number: 600, Model Number: BT43S3S, manufactured by: Advanced Equipment, Inc.), zone #2. The employee is required to go into the blast freezer to inspect the six freezer zones and determine whether to blast off any ice or snow accumulation in the zones. The employee was found by coworkers trapped in freezer zone #2 during a defrost cycle. By the time employees were able to disconnect the airlines to the freezer door and open it, the defrost cycle already affected the employee, who died of asphyxia.

Keywords: Asphyxiated, Caught In, Freezer Compartment

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1592906.015 29 M Fatality Production helpers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close