Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14543128 - Employee killed in fall down elevator shaft

Accident Summary Nr: 14543128 -- Report ID: 0418100 -- Event Date: 02/01/1985
Inspection NrDate OpenedSICNAICSEstablishment Name
196107702/07/198517210Campbell Decorating Company
Inspection NrDate OpenedSICNAICSEstablishment Name
196106902/07/198517310Wright-Brown Electric Company, Inc.
Inspection NrDate OpenedSICNAICSEstablishment Name
196017802/04/198517960Atlanta Elevator Erectors, Inc.
Inspection NrDate OpenedSICNAICSEstablishment Name
196014502/01/198565120Atlantic Realty Company
Inspection NrDate OpenedSICNAICSEstablishment Name
196018602/04/198517420Walls, Incorporated
Inspection NrDate OpenedSICNAICSEstablishment Name
196108502/07/198517110Emc Inc
Inspection NrDate OpenedSICNAICSEstablishment Name
196111902/07/198515420Bcb Company
Inspection NrDate OpenedSICNAICSEstablishment Name
196110102/07/198517110Mckenney'S Inc
Inspection NrDate OpenedSICNAICSEstablishment Name
196109302/07/198517310Johnson Controls Inc

Abstract: Employee #1 and five coworkers rode the Otis freight elevator from the third to the ninth floor. The elevator operator got out of the car and held the hoistway door open. As Employee #1 was exiting, the extension cord he had coiled around his left shoulder became caught on the elevator control, holding it in the 'up' position. The elevator car started up, pulling him into the shaft. He fell to the bottom of the pit, suffering multiple head and body injuries. Employee #1 was killed. The freight elevator had been installed in April, 1924. It had a toggle-type deadman control which, when pushed and held in one direction, took the elevator up, and vice versa. The elevator was being changed to a pulley automatic system. New hoistway doors had been installed but were not yet interlocked, so the elevator was able to move even though the doors were open. The elevator car gate had also been removed.

Keywords: DEADMAN CONTROL, ELEVATOR SHAFT, ELEVATOR GATE, ELEVATOR, FALL, WORK RULES, CONSTRUCTION, INTERLOCK

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1961077 Occupation Not Listed
2 1961069 Occupation Not Listed
3 1960178 Occupation Not Listed
4 1960145 Occupation Not Listed
5 1960186 Fatality Fracture Occupation not reported
6 1961085 Occupation Not Listed
7 1961119 Occupation Not Listed
8 1961101 Occupation Not Listed
9 1961093 Occupation Not Listed

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.