Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14514491 - Employee killed by unsecured Schelling saw

Accident Summary Nr: 14514491 -- Report ID: 0524700 -- Event Date: 05/14/1990
Inspection NrDate OpenedSICNAICSEstablishment Name
10627957305/15/199025310Sauder Woodworking Co.

Abstract: Employee #1 was performing general maintenance on a Schelling saw (#40105) that was not locked out and was not blocked under the beam. He was removing two 1/2 in. hoses and a junction block that were no longer functional. While Employee #1 was pulling on the hoses to see which one to cut and remove, the hoses tripped the micro switch. The left beam, which weighed approximately 1,500 lb, came down and struck his head. Employee #1, who was on his side, rolled onto his back and, when found, apparently had a pulse for only a minute or two. He died. There was no lockout policy/procedure. The three limit switches are 24 volt DC. The saw motor is a 480 volt with manual shut-off.

Keywords: BEAM, HEAD, MAINTENANCE, BLOCKS, WORK RULES, LOCKOUT, SAW, STRUCK BY, FALLING OBJECT, UNGUARDED

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 106279573 Fatality Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close